Example 6.5.8-1 [Ansys WB / Response Spectrum] A cantilever beam of length l has a square section 0.1 x 0.1 in2 and is subjected to a vertical motion of support by displacement spectrum of 1 in. Two point weights of 10 lbf each are attached at mid-point and end point of the beam. Determine the displacement responses of two weights.
The red line give the SRSS value from the RS -analysis Figure 13: X- displacement from the probe location (see Figure 7). The red line give the SRSS value from the RS -analysis and the green line is the absolute value from the RS -analysis (found by manually combining the modes), Apply displacement to the workpiece in y axis in 14 steps: In solution section add Equivalent Von-Mises stress to all body, Equivalent plastic strain to workpiece, directional Deformation to workpiece in z direction and finally directional deformation to front small faces of workpiece in y axis to calculate the displacement . Now Run the solution.
Example 6.5.8-2 [ Ansys WB / Response Spectrum] A cantilever beam of length l has a square section 0.1 x 0.1 in2 and is subjected to a vertical motion of support by displacement spectrum of 1 in. Two point weights of 10 lbf each are attached at mid-point and end point of the beam. Determine the displacement responses of two weights.
Academia.edu is a platform for academics to share research papers.
A displacement sensor (displacement gauge) is primarily used to measure the range of where an object has to travel and in relation to a reference position. Displacement sensors have multiple uses. Its primary use is for dimension measurement.
1/3/2006 · 12) Displacement is selected in the Mode Combinations Method dialog box 13) Solve 14) Read Input From -> select the .mcom file 15) In /Post1 there are three modes which have a signif equal to or higher than 0.001. They are 114 Hz, 607 Hz, and 1460 Hz.
There is fixed support or something else like displacement , remote displacement ? … Response Spectrum – apply base acceleration RS to all fixed supports. … Ansys customers with active commercial software licenses can access the customer portal and submit support questions. You will need your active account number to register.
You specify the frequency range of interest for the random response procedure. The response is calculated at multiple points between the lowest frequency of interest and the first eigenfrequency in the range, between each eigenfrequency in the range, and between the last eigenfrequency in the range and the highest frequency in the range as illustrated in Figure 1.